Authors of section

Authors

Harry Hoyen, Simon Lambert, Joideep Phadnis

Executive Editor

Simon Lambert

Open all credits

Copy Citation

Cerclage compression wire fixation of olecranon osteotomy

1. Cerclage compression wiring

The philosophy behind cerclage compression wiring for the olecranon is that it converts tensile forces on the posterior side of the olecranon into compression forces at the joint line during flexion. The fixation is simple and inexpensive and works well if executed properly.

Choose a wire of sufficient strength to withstand the tensile forces generated in the figure-of-eight loop (1.0 mm). Positioning the K-wires as close to the joint while also penetrating the volar cortex is paramount.

This form of fixation was referred to as a “Tension band fixation”. We now prefer the term “Cerclage compression wire fixation” because the tension band mechanism cannot be applied consistently to each component of the fracture fixation. An explanation of the limits of the Tension band mechanism/principle can be found here.

Tension band principle for fixation of olecranon osteotomy

Teaching video

AO teaching video: Ulna, Olecranon—Transverse Fracture (2U1B1) Cerclage compression wiring

 

2. Reduction

Reduce and hold the osteotomy with pointed reduction forceps to apply compression.

Pearl: To prevent the reduction forceps from slipping on the distal fragment, a small hole can be drilled in the distal fragment before applying the forceps.
Reduce and hold the osteotomy with pointed reduction forceps to apply compression.

3. Preparation of wire insertion

Drilling

Approximately 40 mm distal to the fracture line and at least 5 mm from the posterior cortex, drill a hole through the ulna with a 2.0 mm drill, using a sharp drill guide as the drill tends to slide dorsally.

Approximately 40 mm distal to the fracture line and at least 5 mm from the posterior cortex, drill a hole through the ulna with a 2.0 mm drill.

Wire preparation and insertion

Prepare a 1.0 mm wire by making a loop approximately one third along its length.

Insert the shorter segment of the wire through the drilled hole from medial to lateral. As the ulnar nerve is medial, it is safer to introduce the wire from this side.

Insert the shorter segment of the wire through the drilled hole from medial to lateral.

4. Insertion of K-wires

First K-wire

Using the drill guide, introduce the first 1.6 mm K-wire medially through the proximal end of the olecranon. Aim the drill towards the anterior cortex, passing as close as possible to the joint. Leave enough space on the lateral side for the second K-wire.

Drill the K-wire through both cortices.

Insertion of K-wires for tension band wiring

Second K-wire

Insert the drill guide over the first K-wire, and insert the second 1.6 mm K-wire parallel to the first one.

Insertion of K-wires for tension band wiring

Check the position of both K-wires under image intensification. If the position of wires and osteotomy reduction is good, pull both K-wires back approximately 1 cm.

Provisionally cut the K-wire ends 2 cm above the bone.

Insertion of K-wires for tension band wiring

5. Wire fixation

Figure-of-eight configuration

The small pointed reduction forceps can now be removed.

Pass the long segment of the wire (bearing the loop) in a figure-of-eight configuration beneath the triceps tendon around the protruding ends of the K-wires.

Unite the two wires with a little twist.

Note: Make sure that loop and wire twist do not lie too close to the wire hole to avoid unnecessary tension at the wire hole.
Placing the loops more proximal will allow a smaller incision when removing them after healing.
Pass the long segment of the wire in a figure-of-eight configuration beneath the triceps tendon around the protruding ends of the K-wires.

Tightening the wire

Loosely prepare the wire twist, ensuring that each end of the wire spirals equally – the twist should not comprise one spiral around a straight wire.

Tightening the tension band wire

Cut the wire ends short.

The slack is then taken up by further twisting. Repeat this until the desired tension is achieved. Both loops must be tightened simultaneously and in the same direction to achieve equal tension on both arms of the wire.

By tightening the twist and the loop with two pliers simultaneously, the two fragments are drawn together such that the fracture is placed under compression.

Note: Avoid excessive tensioning, especially in osteoporotic bone.
Tightening the tension band wire

Preventing later soft-tissue irritation

Trim the twisted wire and turn both ends towards the ulna/olecranon not to irritate the soft tissues later.

Turn both wire ends towards the ulna/olecranon not to irritate the soft tissues later.

Sinking the K-wires

With the help of pliers, bending iron, and forceps, bend the proximal end of the K-wires 180°.

Cut the K-wires leaving a bend of about 5–6 mm. Make a small cut in the triceps to allow burial of the K-wires. Then drive the K-wires home, sinking their curved ends into the bone to prevent backing out and skin irritation. Closing the small cut in the triceps over the K-wires will help prevent backing out of the wires.

Tension band fixation of olecranon osteotomy

Checking results

Confirm stability of the fixation and range of motion, including supination/pronation. Check for K-wire impingement of the radioulnar joint. Final x-rays or image intensifier views should demonstrate good reduction and proper hardware position.

Go to diagnosis